Flexible MICA Fire Enclosure for Recessed Fixtures

2 enclosure profile options

Item numbers ↓

Dimensions

2 drawings · click to open full size

Item numbers

2

Both 2 are the same item. Enclosure profile changes.

Item numberEnclosure Profile
FIREENCLStandard
FIREENCL-SShallow

Details

  • Fire Enclosure provides fire barrier around recessed lights. It also can be used as vapor barrier for other openings.
  • Can be installed before or after recessed fixture installation.
  • Easy installation reduces labor costs significantly.
  • 2″ wide nailing flange on all sides.
  • To be used with Mica tape (FIRETAPE sold separately) to seal the power feeding point.
  • ETL approved 1 hour fire rating.
  • FIREENCL Fits both 16″ and 24″ on-center ceiling constructions.
  • FIREENCL-S Fits in 2x8 construction.
  • Install easily with drywall screws with flat washers, nails or staples.
  • Meets the specifications of: UL 263, ASTM E119.
  • For use with ceiling constructions: L528