4″ Cedar™ System Non-IC New Construction LED Double Wall Housing w/ Driver

4″ Cedar™ System Non-IC New Construction LED Double Wall Housing w/ Driver

1600 lm · New Construction · 3 item numbers · Non-IC Frame for non-IC conditions

Item numbers ↓

Item numbers

3

All 3 are the same item. Voltage and dimming change.

Item numberVoltageDimming
E4LC16-2120V120V Triac/ELV
E4LC16D2120-277V120/277V Triac/ELV/0-10V
E4LC16SD120-277VSunset (warm dim)

Details

  • USA designed and assembled.
  • Limited 5 year warranty.
  • For use with ELCO Cedar™ System 4″ LED Light Engines.
  • 2 at the end of the item number denotes Generation 2. Please note Gen 2 and Gen 1 are not cross compatible.
  • Construction

    Non-IC Frame for non-IC conditions. Housing adjusts in frame to accommodate up to 1 1/2″ ceiling thickness.

  • Installation

    Designed for ceiling plenums where 2x6 joists or taller are used. High strength hanger bars can easily be nailed to joists. Suitable for T-grid and drop ceiling applications.See installation sheet for detailed information.

  • Junction Box

    Positioned to accommodate straight conduit runs. Two 3/4″ knockouts, Seven 1/2″ trade size conduit knockouts, One 3/8″ knockout. Four Pry-out knockout slots for easy romex installation.

  • Hanger Bars

    Pre Installed hanger bars with True Nail easy installation in regular lumber, engineered lumber, and Laminated Beams. Integral T-bar slots for easy installation in T-Bars. Spans up 24″ and can be repositioned 90°. Score lines allow for tool-free hanger bar size reduction. Integral leveling flange allows for single-person installation while easily aligning the housings with the joists.

  • Electrical

    Driver is rated for 120V and 277V input (120/277V). High Efficiency driver with a power factor > 0.95.

  • Dimmability

    3 in 1 dimming: Triac, ELV and 0-10V dimming in one driver. Triac/ELV down to 5% on 120V; 0-10V/Triac/ELV down to 1% on 120/277V. For a full list of dimmers refer to the Dimmer Compatibility List.

  • Emergency Battery Pack

    Optional 90 minute battery pack available with test indicator switch. Note that double wall housings require Access From Above Ceiling for Battery Maintenance.

  • Listings

    UL Listed (US and Canada) for Damp Location and for Wet Location with select trims. UL Listed (US and Canada) for Feed Through.