Skip to content
4″ Cedar™ System New Construction Foam Insulated R-60 Housing w/Driver

4″ Cedar™ System New Construction Foam Insulated R-60 Housing w/Driver

120-277V · Triac/ELV/0-10V · IC Airtight · New Construction · 2 lumens · Double wall IC rated for direct contact with insulation

Item numbers ↓

Item numbers

2

Both 2 are the same item. Lumens changes.

Item numberLumens
E4AJ08ICAD2850 lm
E4AJ12ICAD21250 lm

Details

  • Foam insulated R-60 housing for R-60 insulation and Chicago Plenum.
  • Optional 90 minutes, 120/277 VAC, 60Hz, Emergency Backup.
  • USA designed and assembled.
  • Limited 5 year warranty.
  • For use with ELCO Cedar™ System 4″ LED Light Engines.
  • 2 at the end of the item number denotes Generation 2. Please note Gen 2 and Gen 1 are not cross compatible.
  • Construction

    Double wall IC rated for direct contact with insulation. For use in IC and non-IC conditions. Up to 1250 lumens. Housing adjusts in frame to accommodate up to 1 1/2″ ceiling thickness. Airtight housing with gasket to restrict airflow in accordance with ASTM E-283 air-tight requirements.

  • Installation

    Designed for ceiling plenums where 2x6 joists or taller are used. High strength hanger bars can easily be nailed to joists. Suitable for T-grid and drop ceiling applications. See installation sheet for detailed information. Emergency Battery Back-up Option requires access from above.

  • Junction Box

    Positioned to accommodate straight conduit runs. Two 3/4″ knockouts.

  • Hanger Bars

    Pre Installed hanger bars with True Nail easy installation in regular lumber, engineered lumber, and Laminated Beams. Integral T-bar slots for easy installation in T-Bars. Spans up 24″ and can be repositioned 90°. Score lines allow for tool-free hanger bar size reduction. Integral leveling flange allows for single-person installation while easily aligning the housings with the joists.

  • Electrical

    Driver is rated for 120V and 277V input (120/277V). High Efficiency driver with a power factor > 0.95.

  • Emergency Battery Pack

    Optional 90 minute battery pack available with test indicator switch. Note that double wall housings require Access From Above Ceiling for Battery Maintenance.

  • Dimmability

    3 in 1 dimming: Triac, ELV and 0-10V dimming in one driver. Triac/ELV down to 5% on 120V; 0-10V/Triac/ELV down to 1% on 120/277V. For a full list of dimmers refer to the Dimmer Compatibility List.

  • Listings

    UL Listed (US and Canada) for Damp Location and for Wet Location with select trims. UL Listed (US and Canada) for Direct Contact with Insulation and Combustible Material. UL Listed (US and Canada) for Feed Through.